FAA Issues SAIB For TKS Fluid

Potential Fire Hazard Not Know At Initial Certification

The FAA has issued a Special Airworthiness Information Bulletin for TKS de-icing fluid due to a potential flammability hazard. At this time, this airworthiness concern is not considered an unsafe condition that would warrant an airworthiness directive action.

In prior certifications of TKS systems on board aircraft, the issue of fluid flammability was not a concern; the fluid was simply considered to be non-flammable. However, recent testing has shown that the fluid is in fact flammable under certain conditions.

Per 14 CFR §23.863(b)(2), it is appropriate to consider the flammability characteristics of the specific fluid in question. In 2008, flammability testing of TKS fluid was documented by the FAA Technical Center in Report No. DOT/FAA/AR-TN08/9. The findings of the Technical Center report are that the TKS fluid is flammable only under very specific conditions:

  • Sustained surface ignition will sometimes occur if a pool of fluid is heated to approximately 150°F and an ignition source is introduced. Above approximately 150°F the ignition is self-extinguishing. However, sustained surface ignition will occur if a pool of fluid is heated to approximately 250°F and an ignition source is introduced.
  • A spray mist will ignite when exposed to a flame, but is not self-sustaining when the ignition source is removed.
  • A spray mist will undergo “sporadic ignitions” confined to small areas when exposed to a spark, but is not self-sustaining.

It was determined that drip or stream directed onto a hot surface will not igniteIn short, the fluid is only self-sustainingly flammable when allowed to both pool and heat. Further, a spray mist is only flammable in the presence of a sustained ignition source. In essence the report supports the argument that it is appropriate in certain conditions to treat the fluid as non-flammable.

The FAA recommends that all type certificate, amended type certificate, and supplemental type certificate applicants assess the pertinent regulations (14 CFR, part 23, §23.853(e), §23.863, and §23.1365(c)) for their TKS system and take any appropriate action. Specifically:

  • 14 CFR, part 23, §23.853(e), which requires lines, tanks, and other equipment containing flammable fluids not be installed in passenger compartments unless shielded, isolated, or otherwise protected such that the fluid is not a hazard.
  • 14 CFR, part 23, §23.863, which requires minimization of the probability of ignition of fluids and vapors for each area where flammable fluids or vapors could escape.
  • 14 CFR, part 23, §23.1365(c), which requires main power cables be separated from TKS fluid lines or be shrouded by electrically insulated flexible conduct or equivalent, in addition to the normal cable insulation.

The FAA says that TKS anti-icing fluid requires consideration of flammability characteristics in order to determine its appropriate classification. FAA testing has revealed that the fluid must be considered as flammable under certain conditions. Specifically, TKS fluid must be considered flammable when fluid pooling may occur under conditions that may then elevate the temperature of the pool to a level that would support sustained combustion. The agency further states that TKS fluid must also be considered flammable when conditions could present a situation where a fine spray is directed onto a sustained flame source.

FMI: www.faa.gov

 


Advertisement

More News

ANN's Daily Aero-Term (04.30.24): Runway Centerline Lighting

Runway Centerline Lighting Flush centerline lights spaced at 50-foot intervals beginning 75 feet from the landing threshold and extending to within 75 feet of the opposite end of t>[...]

ANN's Daily Aero-Linx (04.30.24)

Aero Linx: Air Force Global Strike Command Air Force Global Strike Command, activated August 7, 2009, is a major command with headquarters at Barksdale Air Force Base, Louisiana, i>[...]

Airborne 04.24.24: INTEGRAL E, Elixir USA, M700 RVSM

Also: Viasat-uAvionix, UL94 Fuel Investigation, AF Materiel Command, NTSB Safety Alert Norges Luftsportforbund chose Aura Aero's little 2-seater in electric trim for their next gli>[...]

Airborne 04.29.24: EAA B-25 Rides, Textron 2024, G700 Deliveries

Also: USCG Retires MH-65 Dolphins, Irish Aviation Authority, NATCA Warns FAA, Diamond DA42 AD This summer, history enthusiasts will have a unique opportunity to experience World Wa>[...]

Airborne-NextGen 04.23.24: UAVOS UVH 170, magni650 Engine, World eVTOL Directory

Also: Moya Delivery Drone, USMC Drone Pilot, Inversion RAY Reentry Vehicle, RapidFlight UAVOS has recently achieved a significant milestone in public safety and emergency services >[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC