FAA Issues SAIB Concerning Jet Fuel Supplies

Warns Of Possible Migration Of  Super Absorbent Polymer (SAP) Filter Media Particles Into Aircraft Fuel Supplies

The FAA has issued a Special Airworthiness Information Bulletin (SAIB) concerning the possible migration of Super Absorbent Polymer (SAP) filter media particles into aircraft fuel supplies. The SAP media is the filter element material utilized in ground-based water filtration systems called filter monitors to absorb water from the fuel before it enters the aircraft.

Airlines for America issued Bulletin 2017.2, “Modified ATA103 Requirements for Filter Monitors”, dated December 11, 2017, and Bulletin 2018.1, “Update on ATA103 Requirements for Filter Monitors”, dated June 5, 2018, describing six actions intended to inhibit or prevent the migration of SAP media into the fuel supply. In addition, the Energy Institute (EI) published a bulletin in December 2017, “IATA Super-absorbent Polymer (SAP) Special Interest Group – Data summary and proposed roadmap,” describing the work of that group and associated recommended preventive measures. The recommended actions in the A4A bulletins include the limiting of maximum filter monitor differential pressure to 15 psi, replacement of filter elements with the newest edition elements, and cleaning of hose-end nozzle strainer screens using an improved procedure. The EI bulletin describes the same actions but has not been updated with the current target dates for completing the recommended actions. The EI bulletin also describes a plan for the eventual replacement of filter monitors with new technology filtering systems within the next three years.

The SAIB recommends that airplane operators, FBOs, FAA repair stations, FSDOs, and foreign civil aviation authorities review the information in the A4A bulletins with into-plane re-fueling operators for compliance with the recommended actions.

Filter monitors are constructed as cylindrical vessels that contain approximately 25 to 35 cylindrical filter elements. The active media in the filter elements is SAP, which absorbs water from the fuel as it flows over the element. Filter monitor manufacturers qualify their products to an industry specification published by the Energy Institute: EI 1583, “Laboratory Tests and Minimum Performance Levels for Aviation Fuel Filter Monitors.” The concern with SAP migration had existed since the early 2000’s when airlines had to reduce their aircraft fuel filter replacement intervals due to an increase in reported fuel filter bypass incidents and the U.S. Air Force (USAF) experienced engine flameouts caused by SAP clogging of engine fuel 2 filters.

The USAF concluded that the use of Fuel System Icing Inhibitor in jet fuel could induce SAP media migration into the jet fuel loaded on to the aircraft and permanently removed filter monitors from their ground refueling operations. The civilian fleet of aircraft continued to use filter monitors, but an industry investigation was initiated in response to the fuel filter replacement reports. As a result of the industry investigation, in 2009 the 6th edition of EI 1583 added a test intended to identify filters that were prone to SAP migration.

The concern was renewed in April 2010, when a Cathay Pacific Airlines Airbus A330 experienced engine control problems that resulted in an emergency landing. The incident was determined to be caused by SAP contamination of the aircraft fuel system due to an over pressurization of the filter monitor during aircraft refueling. Since this incident, there have been seven additional aircraft events where investigators determined SAP was the cause of operability issues for the aircraft operator. Recent bench testing of the current design filter monitor elements has shown that they can release SAP, particularly at differential pressures above 15 psi under normal operating conditions, and filter monitor manufacturers and SAP manufacturers cannot guarantee that trace amounts of SAP will not pass downstream of filter monitor elements when in service.

The FAA is monitoring the situation to determine if additional action is required. The agency is are requesting that any service difficulties and maintenance and inspection findings on aircraft that are suspected of experiencing SAP contamination should be reported to us in support of this effort.

The FAA recommends the following:
Review A4A Bulletin 2017.2, “Modified ATA103 Requirements for Filter Monitors”, dated December 11, 2017, and Bulletin 2018.1, “Update on ATA103 Requirements for Filter Monitors”, dated June 5, 2018 with into-plane re-fueling operators for compliance with the recommended actions described in the bulletin.
Consult EI bulletin “IATA SAP Special Interest Group – Data summary and proposed roadmap,” published in December 2017, with into-plane re-fueling operators for additional information relating to this issue.

(Source: FAA)

FMI: SAIB

Advertisement

More News

Airborne-Flight Training 05.09.24: ERAU at AIAA, LIFT Diamond Buy, Epic A&P

Also: Vertical Flight Society, NBAA Maintenance Conference, GA Honored, AMT Scholarship For the first time, students from Embry-Riddle’s Daytona Beach, Florida, campus took t>[...]

ANN's Daily Aero-Term (05.07.24): Hazardous Weather Information

Hazardous Weather Information Summary of significant meteorological information (SIGMET/WS), convective significant meteorological information (convective SIGMET/WST), urgent pilot>[...]

Aero-News: Quote of the Day (05.07.24)

"The need for innovation at speed and scale is greater than ever. The X-62A VISTA is a crucial platform in our efforts to develop, test and integrate AI, as well as to establish AI>[...]

NTSB Final Report: Cessna 150

(FAA) Inspector Observed That Both Fuel Tanks Were Intact And That Only A Minimal Amount Of Fuel Remained In Each Analysis: According to the pilot, approximately 8 miles from the d>[...]

Aero-News: Quote of the Day (05.08.24)

“Pyka’s Pelican Cargo is unlike any other UAS solution on the market for contested logistics. We assessed a number of leading capabilities and concluded that the Pelica>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC