Urgent CASA AD: Bell

Emergency Floatation Reservoir Adapter 13/2005
Applicability:
Bell Helicopter Textron Model 212, helicopters modified with Aeronautical
Accessories, Inc. (AAI), Supplemental Type Certificate (STC) SH2820SO; or with
AAI Parts Manufacturer Approval (PMA) reservoir assembly, part number (P/N)
212-372-050; or with adapter, P/N 212-371-002, installed.

Requirement: 1. Vent the nitrogen from the reservoir assembly by following the Accomplishment
Instructions, Part II - Floatation System Discharging, of AAI Alert Service
Bulletin (ASB) No. AA-05005, Revision A dated 27 June 27 2005 or later FAA
Approved revision.

2. Remove the valve assembly and air line from the adapter, and inspect the counter
bore depth (dimension D) as shown in Figure 1 of the ASB.
(a) If dimension D, as depicted in Figure 1 of the ASB, does not exceed .860
inch, recharge the floatation system by following the Accomplishment
Instructions, Part III - Floatation System Charging, and referring to Figures 2
and 3 of the ASB.
(b) If dimension D, as depicted in Figure 1 of the ASB, exceeds .860 inch,
replace the reservoir assembly and the adapter with serviceable parts.

3. Discharging and recharging the floatation system and inspecting the counter bore
depth dimension of the adapter shall be done in accordance with the specified
portions of the ASB.
Note: FAA AD 2005-20-38 Amendment 39-14335 refers.

Compliance: 1. Within the next 24 hours time-in-service (TIS) or before the next emergency floatation supply bottle nitrogen charging after the effective date of this AD.
2. Within the next 24 hours time-in-service (TIS) or before the next emergency
floatation supply bottle nitrogen charging after the effective date of this AD.
2. (b) Before further flight after the effective date of this AD.
3. From the effective date of this AD.

This Airworthiness Directive becomes effective on 9 November 2005.

Background: The actions detailed in this AD are intended to prevent rupture of an adapter, uncontrolled jetting of pressurized gas from the nitrogen bottle, and subsequent injury to occupants or damage to the helicopter.

FMI: www.casa.gov.au

Advertisement

More News

ANN's Daily Aero-Term (04.28.24): Airport Marking Aids

Airport Marking Aids Markings used on runway and taxiway surfaces to identify a specific runway, a runway threshold, a centerline, a hold line, etc. A runway should be marked in ac>[...]

Aero-News: Quote of the Day (04.28.24)

"It is extremely difficult, if not impossible, for manned aircraft to see a drone while conducting crop-enhancing and other aerial applications at low altitudes and high speeds. We>[...]

ANN's Daily Aero-Linx (04.28.24)

Aero Linx: The Skyhawk Association The Skyhawk Association is a non-profit organization founded by former Skyhawk Pilots which is open to anyone with an affinity for the A-4 Skyhaw>[...]

Aero-News: Quote of the Day (04.29.24)

“The T-54A benefits from an active Beechcraft King Air assembly line in Wichita, Kansas, where all required METS avionics and interior modifications are installed on the line>[...]

ANN's Daily Aero-Linx (04.29.24)

Aero Linx: Aerostar Owners Association The Association offers the Aerostar Owner a unique opportunity to tap an invaluable source of information concerning the care and feeding of >[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC