Urgent CASA AD: Dassault

Applicability: Falcon 2000EX aeroplanes with serial number (S/N) 06, 28 through 90, 93 and 95.

Requirement:
  1. Perform an engine fire detection integrity check in accordance with Dassault Aviation Service Bulletin (SB) F2000E X-137 dated 23 November 2006 or later EASA approved revision.
  2. If, as a result of the Requirement 1 integrity check, if either one or both the LH or the RH system is (are) found to be incorrect, check the actual resistance of both detectors of the incorrect system(s) on the affected engine(s) in accordance with (SB) F2000E X-137 or later EASA approved revision.
  3. Replace any detector that is determined to be faulty during the Requirement 2 resistance check.

Note: EASA Emergency AD 2006-0356-E refers.

Compliance: For Requirement 1 - No later than 5 January 2007. For Requirements 2 and 3 - Before further flight after either the Requirement 1 or 2 check, as applicable.

This Airworthiness Directive becomes effective on 4 December 2006.

Background: The European Aviation Safety Agency (EASA) has advised that troubleshooting of a "ENG 1 FIRE DETECT FAIL" CAS message that occurred on an in-service aircraft revealed that the detector threshold tolerances could not identify a single failure of one engine fire detector loop out of the two present on each engine. The fire detection system is therefore not correctly monitored, and its integrity is not guaranteed at all times. The aim of this Directive is to verify the fire detection system integrity by mandating a one time inspection and, if necessary, the replacement of faulty detector pending further modification of the monitoring system.

FMI: www.casa.gov.au

Advertisement

More News

Airbus Racer Helicopter Demonstrator First Flight Part of Clean Sky 2 Initiative

Airbus Racer Demonstrator Makes Inaugural Flight Airbus Helicopters' ambitious Racer demonstrator has achieved its inaugural flight as part of the Clean Sky 2 initiative, a corners>[...]

Diamond's Electric DA40 Finds Fans at Dübendorf

A little Bit Quieter, Said Testers, But in the End it's Still a DA40 Diamond Aircraft recently completed a little pilot project with Lufthansa Aviation Training, putting a pair of >[...]

ANN's Daily Aero-Term (04.23.24): Line Up And Wait (LUAW)

Line Up And Wait (LUAW) Used by ATC to inform a pilot to taxi onto the departure runway to line up and wait. It is not authorization for takeoff. It is used when takeoff clearance >[...]

NTSB Final Report: Extra Flugzeugbau GMBH EA300/L

Contributing To The Accident Was The Pilot’s Use Of Methamphetamine... Analysis: The pilot departed on a local flight to perform low-altitude maneuvers in a nearby desert val>[...]

Classic Aero-TV: 'Never Give Up' - Advice From Two of FedEx's Female Captains

From 2015 (YouTube Version): Overcoming Obstacles To Achieve Their Dreams… At EAA AirVenture 2015, FedEx arrived with one of their Airbus freight-hauling aircraft and placed>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC