AD: Boeing Company Airplanes | Aero-News Network
Aero-News Network
RSS icon RSS feed
podcast icon MP3 podcast
Subscribe Aero-News e-mail Newsletter Subscribe

Airborne Unlimited -- Most Recent Daily Episodes

Episode Date

Airborne-Monday

Airborne-Tuesday

Airborne-Wednesday Airborne-Thursday

Airborne-Friday

Airborne On YouTube

Airborne-Unlimited-05.13.24

Airborne-NextGen-05.14.24

Airborne-Unlimited-05.15.24 Airborne-AffordableFlyers-05.16.24

Airborne-Unlimited-05.17.24

Sun, Nov 15, 2020

AD: Boeing Company Airplanes

AD 2020-22-15 Requires An Inspection Of The Overwing Floor Beams

The FAA is adopting a new airworthiness directive (AD) for all The Boeing Company Model DC-10-10 and DC-10-10F airplanes, Model DC-10-15 airplanes, Model DC-10-30 and DC10-30F (KC-10A and KDC-10) airplanes, Model DC-10-40 and DC-10-40F airplanes, Model MD10-10F and MD-10-30F airplanes, and Model MD-11 and MD-11F airplanes. This AD was prompted by reports of cracked floor beams and floor beam supports in the area of the overwing exit doors located at certain stations (STA). This AD requires an inspection of the overwing floor beams for any repair, repetitive inspections of the overwing floor beams and floor beam supports at certain STA on the left and right sides for any crack, and applicable on-condition actions. The FAA is issuing this AD to address the unsafe condition on these products. This AD is effective December 18, 2020.

Supplementary Information: The FAA issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 by adding an AD that would apply to all The Boeing Company Model DC-10-10 and DC-10-10F airplanes, Model DC-10-15 airplanes, Model DC-10-30 and DC-10-30F (KC-10A and KDC-10) airplanes, Model DC-10-40 and DC-10-40F airplanes, Model MD-10-10F and MD-10-30F airplanes, and Model MD-11 and MD-11F airplanes. The NPRM published in the Federal Register on August 25, 2020 (85 FR 52287). The NPRM was prompted by reports of cracked floor beams and floor beam supports in the area of the overwing exit doors located at certain STA. The NPRM proposed to require an inspection of the overwing floor beams for any repair, repetitive inspections of the overwing floor beams and floor beam supports at certain STA on the left and right sides for any crack, and applicable on-condition actions.

The FAA is issuing this AD to address potential undetected overwing floor beam cracks that could grow in length until the floor beam severs, and, if limit load is applied with two adjacent severed floor beams, could adversely affect the structural integrity of the airplane, which could result in the loss of primary control systems and lead to reduced controllability of the airplane.

FMI: www.regulations.gov

Advertisement

More News

Classic Aero-TV: Remembering Bob Hoover

From 2023 (YouTube Version): Legacy of a Titan Robert (Bob) Anderson Hoover was a fighter pilot, test pilot, flight instructor, and air show superstar. More so, Bob Hoover was an i>[...]

ANN FAQ: Follow Us On Instagram!

Get The Latest in Aviation News NOW on Instagram Are you on Instagram yet? It's been around for a few years, quietly picking up traction mostly thanks to everybody's new obsession >[...]

ANN's Daily Aero-Linx (05.15.24)

Aero Linx: B-52H Stratofortress The B-52H Stratofortress is a long-range, heavy bomber that can perform a variety of missions. The bomber is capable of flying at high subsonic spee>[...]

ANN's Daily Aero-Term (05.15.24):Altimeter Setting

Altimeter Setting The barometric pressure reading used to adjust a pressure altimeter for variations in existing atmospheric pressure or to the standard altimeter setting (29.92).>[...]

Aero-News: Quote of the Day (05.16.24)

"Knowing that we play an active part in bettering people's lives is extremely rewarding. My team and I are very thankful for the opportunity to be here and to help in any way we ca>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC