AD: ATR-GIE Avions de Transport Régional Airplanes

AD 2021-09-18 Requires Modifying The Electrical Harness Routes And De-Icing Pipe Coupling Installations

The FAA is adopting a new airworthiness directive (AD) for certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes.

This AD was prompted by a report of an engine electrical control #1 fault during flight caused by chafing damage on an electrical harness bundle. This AD requires modifying the electrical harness routes and de-icing pipe coupling installations, as specified in a European Union Aviation Safety Agency (EASA) AD, which is incorporated by reference. The FAA is issuing this AD to address the unsafe condition on these products. This AD is effective July 1, 2021.

Supplementary Information: The EASA, which is the Technical Agent for the Member States of the European Union, has issued EASA AD 2020-0227, dated October 19, 2020 (EASA AD 2020-0227) (also referred to as the Mandatory Continuing Airworthiness Information, or the MCAI), to correct an unsafe condition for certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes.

The FAA issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 by adding an AD that would apply to certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes. The NPRM published in the Federal Register on February 22, 2021 (86 FR 10491). The NPRM was prompted by a report of an engine electrical control #1 fault during flight caused by chafing damage on an electrical harness bundle. The NPRM proposed to require modifying the electrical harness routes and de-icing pipe coupling installations, as specified in EASA AD 2020-0227.

The FAA is issuing this AD to address chafing damage on an electrical harness bundle, which could result in wire failure and a short circuit, an uncontrolled fire, and consequent loss of multiple systems, possibly resulting in reduced controllability of the airplane. See the MCAI for additional background information.

FMI: www.regulations.gov

Advertisement

More News

Airborne 05.10.24: Icon Auction, Drunk MedEvac Pilot, Bell ALFA

Also: SkyReach Parts Support, Piper Service Ctr, Airliner Near-Miss, Airshow London The Judge overseeing Icon's convoluted Chapter 11 process has approved $9 million in Chapter 11 >[...]

ANN's Daily Aero-Term (05.13.24): ILS PRM Approach

ILS PRM Approach An instrument landing system (ILS) approach conducted to parallel runways whose extended centerlines are separated by less than 4,300 feet and at least 3,000 feet >[...]

ANN's Daily Aero-Linx (05.13.24)

Aero Linx: FlyPups FlyPups transports dogs from desperate situations to fosters, no-kill shelters, and fur-ever homes. We deliver trained dogs to veterans for service and companion>[...]

Airborne-NextGen 05.07.24: AI-Piloted F-16, AgEagle, 1st 2 WorldView Sats

Also: Skydio Chief, Uncle Sam Sues, Dash 7 magniX, OR UAS Accelerator US Secretary of the Air Force Frank Kendall was given a turn around the patch in the 'X-62A Variable In-flight>[...]

Airborne 05.08.24: Denali Update, Dad-Daughter Gyro, Lake SAIB

Also: NBAA on FAA Reauth, DJI AG Drones, HI Insurance Bill Defeated, SPSA Airtankers The Beechcraft Denali continues moving forward towards certification, having received its FAA T>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC