Thu, Dec 01, 2005

CASA Urgent AD: Bell Helicopter

Applicability: Bell Helicopter Textron Canada (BHTC), Model 206 series helicopters as follows: Model 206A, 206B Serial Numbers (S/N) 004 through 660 and 672 through 715 661 through 671 and 716 through 4586 and 5101 through 5305

Requirement: 1. Inspect the grounding of the fuel pumps and solenoid valve, as per instructions provided in Part I of Alert Service Bulletin (ASB) 206-05-103, dated 11 February 2005, or later revisions approved by the Chief, Continuing Airworthiness, Transport Canada.
2. Helicopters which have incorporated the modification consisting of relocation of the purge hose, as per instructions provided in Part II of (ASB) 206-05-103 (Requirement 2 of the initial issue of this Directive), are to restore the purge hose to the previous configuration, which existed prior to the introduction of this Alert Service Bulletin.

Note: Transport Canada AD CF-2005-10R1 refers.

Compliance: For Requirement 1 - Remains unchanged as “Within the next 100 hours time in service, but no later than 10 July 2005”.
For Requirement 2 - Before further flight after 29 December 2005.

This Amendment becomes effective on 2 December 2005.

Background: Transport Canada has advised that inadequate electrical grounding of the fuel boost pump and the fuel drain solenoid valve, combined with fuel hoses contact, could cause arcing in the main fuel cell which may in turn cause an explosion and resultant fire. The original issue of this Directive required a one time inspection to ensure correct grounding and, if necessary the disconnection and stowage of the engine fuel purge hose. Since Canadian Airworthiness Directive CF-2005-10 was issued, Transport Canada has determined that the purge hose relocation as per instructions provided in Part II of ASB 206-05-103, could cause an engine flameout in a low fuel, boost pump off, condition.

Therefore, until further notice, Requirement 2 of the initial issue of this Directive is revoked and this Amendment requires the helicopter fuel purge hose to be returned to its previous configuration.

The original issue of this Directive became effective on 16 June 2005.

FMI: www.casa.gov.au

Advertisement

More News

ANN's Daily Aero-Term (04.25.24): Airport Rotating Beacon

Airport Rotating Beacon A visual NAVAID operated at many airports. At civil airports, alternating white and green flashes indicate the location of the airport. At military airports>[...]

ANN's Daily Aero-Linx (04.25.24)

Aero Linx: Fly for the Culture Fly For the Culture, Inc. is a 501(c)(3) non-profit organization that serves young people interested in pursuing professions in the aviation industry>[...]

Klyde Morris (04.22.24)

Klyde Is Having Some Issues Comprehending The Fed's Priorities FMI: www.klydemorris.com>[...]

Airborne 04.24.24: INTEGRAL E, Elixir USA, M700 RVSM

Also: Viasat-uAvionix, UL94 Fuel Investigation, AF Materiel Command, NTSB Safety Alert Norges Luftsportforbund chose Aura Aero's little 2-seater in electric trim for their next gli>[...]

Airborne 04.22.24: Rotor X Worsens, Airport Fees 4 FNB?, USMC Drone Pilot

Also: EP Systems' Battery, Boeing SAF, Repeat TBM 960 Order, Japan Coast Guard H225 Buy Despite nearly 100 complaints totaling millions of dollars of potential fraud, combined with>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC